| Channels | 32 |
| MEMORY TOTAL/PER CHANNEL | 32Mbits/1Mbits |
| INTERFACE | USB 2.0 (1.1) |
| OPERATING SYSTEM | Win98/98SE/Me/2000/XP |
| TIMING ANALYSIS | Maximum 200MHz |
| STATE ANALYSIS | 0.001Hz ~ 100MHz |
|
TRIGGER | |
| Channel | 32 |
| Condition | Edge/Pattern |
| Pre/Post trigger | 0%~100% |
| Level | 1 |
| Threshold | +6V ~ -6V |
| Accuracy | ±93mV |
| Delay | Time delay, clock event delay |
| Count | 1 ~ 65535 |
| Page | Maximum 8191 |
|
INPUT | |
| Maximum Input Voltage | ±30V |
| Impedance | 500kΩ/10pF |
| Data Skew | < 1.5ns |
|
ENABLE QUALIFIER | |
| Channel | 32 |
| Enable Condition | Don't care, Low, High |
| Enable Delay |
1 ~ 65535ms |
|
DATA | |
| Compression Channels |
24 |
| Compression Ratio | Maximum 255 |
| Signal Statistics |
Postive/Negative, Full cycle within length condition |
| Protocol Analyzer |
I2C, RS-232C |
|
CURRENT CONSUMPTION | |
| Static | Maximum 200mA |
| Working | Maximum 400mA |
|
POWER DISSIPATION | |
| Static | Maximum 1W |
| Working | Maximum 2W |
|
POWER | |
| Interface | USB |
| Working Voltage | 4.5V ~ 5.5V |
|
TEMPERATURE | |
| Operating | 0°C ~ 50°C |
| Storage | -40°C ~ 80°C |
| DIMENSIONS & WEIGHT |
102(D) x 39 (H) x 137(W) mm |
| Remark : | The specifications apply under the following conditions: GLA is powered on for at least 30 minutes, within +20°C ~ +30°C |