| VERTICAL SYSTEM |
| Sensitivity |
2mV ~ 5V/DIV, 11 steps in 1-2-5 sequence |
| Sensitivity Accuracy |
£3% (5 DIV at the centre of the display) |
| Vernier Vertical Sensitivity |
Continuously variable to 1/2.5 or less of panel-indicate value |
| Frequency Bandwidth (-3dB) |
DC ~ 100MHz DC ~ 20MHz at 2mV/DIV |
| Rise Time |
3.5ns (17.5ns at 2mV/DIV) |
| Signal Delay |
Leading edge can be monitored |
| Maximum Input Voltage |
400V (DC + AC peak) at 1kHz or less |
| Input Coupling Mode |
AC, DC, GND |
| Input Impedance |
1MW ±2%//approx 25pF |
| Vertical Modes |
CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 INV |
| Bandwidth Limited |
20MHz |
| Common-Mode Rejection Ratio |
50:1 or better at 50kHz W |
| X-Y OPERATION |
| Mode |
X-axis: selectable CH1, CH2, EXT Y-axis: selectable CH1, CH2, CH1 and CH2 |
| Sensitivity Accuracy |
2mV ~ 5V/DIV ±3% EXT 0.1V/DIV ±5% |
| X-Axis Bandwidth |
DC ~ 500kHz (-3dB) |
| Phase Error |
Less than 3° at DC ~ 50kHz |
| HORIZONTAL DEFLECTION SYSTEM |
| Horizontal Modes |
MAIN(A), ALT, DELAY(B) |
| A (Main) Sweep Time |
50ns ~ 0.5s/DIV, continuously variable (UNCAL)
|
| B (Delay) Sweep Time |
50ns ~ 50ms/DIV |
| Accuracy |
±3% (±5% at x10 MAG) |
| Sweep Magnification |
x10 (maximum sweep time 5ns/DIV) |
| Hold Off Time |
Variable |
| Delay Time |
1µs ~ 5ms |
| Delay Time Jitter |
1:20000 or less |
| Alternate Separation |
Variable |
| TRIGGER SYSTEM |
| Trigger Modes |
AUTO, NORM, TV |
| Trigger Source |
CH1, CH2, LINE, EXT |
| Trigger Coupling |
AC, DC, HFR, LFR |
| Trigger Slope |
"+" or "-" polarity or TVsync polarity |
| Trigger Sensitivity |
| Mode |
Frequency |
INT |
EXT |
| AUTO |
10Hz ~ 20MHz 20MHz ~ 100MHz |
0.35 DIV 1.5 DIV |
50mV 150mV |
| NORM |
DC ~ 20MHz 20MHz ~ 100MHz |
0.35 DIV 1.5 DIV |
50mV 150mV |
| TV |
Sync signal |
1 DIV |
200mV pp | |
| TV Sync |
TV-V, TV-H |
| Maximum External Input Voltage |
400V (DC + AC peak) at 1kHz |
| External Input Impedance |
1MW ±5%//approx 25pF |
| OUTPUT SIGNAL |
| Trigger Signal Output |
Voltage: approx 25mV/DIV into 50W Frequency Response: DC ~ 10MHz |
| Calibrator Output |
2V pp ±2%, 1kHz square wave |
| CATHODE RAY TUBE |
| Type |
6" rectangular screen with internal graticule; 0%, 10%, 90% and 100% markers |
| Display Area |
8 x 10 DIV (1 DIV = 10mm) |
| Phosphor |
P31 |
| Accelerating Potential |
16kV approx |
| Illumination |
Continuously variable |
| Z-Axis Input |
Coupling: DC Sensitivity: 5V or more Maximum input voltage: 30V (DC + AC peak) at 1kHz or less Bandwidth: DC ~ 5MHz |
| CURSOR READOUT |
| Cursor Measurement Functions |
7 functions: DV, DV%, DVdB, DT, 1/DT, DT%, PHASE |
| Readout Resolution |
1/100 DIV |
| Effective Cursor Range |
Vertical ±3DIV Horizontal ±4DIV |
| Panel Setting Display |
Vertical: V/DIV (CH1, CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND Horizontal: S/DIV(MTB,DTB), UNCAL, x10MAG, delay time, HO Trigger: source, coupling, slope, LEVEL, TV-V, TV-H Others: X-Y, LOCK, SAVE/RECALL MEM 0-9 |
| SPECIAL FUNCTIONS |
| TIME/DIV Auto Range |
Provided |
| Panel Setting Save & Recall |
10 sets |
| Panel Setups Lock |
Provided |
| GENERAL |
| Temperature & Humidity |
Operation range: 0°C ~ 40°C, 85% RH Range rated for use: 10°C ~ 35°C, 85% RH |
| Power Source |
115V, 230V AC ±15% 50/60Hz Approx 60W (70W maximum) |
| Dimensions |
310mm (width) x 150mm (height) x 455mm (depth) |
| Weight |
Approx 9kg |
| Accessories |
Two probes (10:1 / 1:1) and instruction manual |